Bluetrend (Shanghai) Industrial Equipment Co., Ltd.

We are good quality supplier of Electric actuators Motorized Butterfly Valve from China.

About Us
Factory Tour
Quality Control
Contact Us
Home ProductsPneumatic Air Actuator

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator

  • Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator
Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator
Product Details:
Place of Origin: China
Brand Name: ACKO
Certification: CE ISO
Model Number: DA/SR-45......350
Payment & Shipping Terms:
Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: standard sea worthy packing
Delivery Time: 7-14 working days
Payment Terms: T/T
Supply Ability: 100 sets per week
Contact Now
Detailed Product Description
Name: Air Operated Valve Actuators Standard Or Nonstandard: Standard
Acting Mode: Double Acting, Single Acting (Spring Return) Apply: Industry
Seal: Rubber Or Silicone Rubber Sealing Material: NBR, EPDM, FKM (VITON), PTFE (TEFLON)
High Light:

air operated valve actuators

,

air torque actuators

 

 

High Pressure Pneumatic Air Actuator , Air Torque Spring Loaded Double Acting Actuator​

 

A pneumatic actuator is a tool that converts compressed air into mechanical motion. The actuator type determines whether the motion is rotary or linear. There are many different pneumatic actuator types available on the market.

How does the Actuator Work?

The actuator is made up of several different parts, which include: a piston, cylinder, valve, and ports. A diaphragm encloses the pistons, which helps to keep air in the top section of the cylinder. This allows air pressure to bring power to the diaphragm in a downward motion, which moves the piston underneath. When the piston reaches this area the valve stem moves causing the actuator’s internal pieces to move. Each different type of Actuator is capable of a specific application:

 

Pneumatic actuator working principle

 

1, double acting actuator
A port intake, B port exhaust, push the two pistons separately to the two B port intake, A port exhaust, push the two pistons close to the center
While moving, the output shaft turns the valve counterclockwise to open the heart, and the output shaft rotates the valve clockwise to close.

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 0

 

2, single acting actuator
A port intake, B port exhaust, push the two pistons separately to the two exhaust or power loss, the spring pushes the two pistons close to the center
While moving, compress the spring at the same time, the output shaft moves counterclockwise, and the output shaft rotates the valve clockwise to close.
Turn to the direction. Valve open

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 1

 


 

Standard technical parameters

 

 

Indicator

NUMUR standard indicator, easy to install valve accessories such as limit switch, positioner.

 

Output shaft

Plating nickel alloy steel, high precision one-piece output shaft in accordance with NAMUR, with ISO5211

DIN3337 standard.

 

Cylinder

ASTM6005 die-casting aluminum alloy cylinder, with hard anodized

 

End caps

Die-casting aluminum powder spraying a variety of colors

 

Pistons

Double piston rack, adopts hard anodized aluminum or cast steel galvanized processing, symmetric mounting position, fast operation, long service life, simple upside down the piston can change the direction of rotation.

 

Travel adjustment

Two independent stroke adjustment screws can be easily and precisely adjustable of ?5 ?open and closed position.

 

Spring

High performance springs using high quality materials, coating treatment, pre-loading assembly.

 

Simply remove

the single-acting actuator, by changing spring quantity to meet different torque output range.

 

Bearing

Bearings, guide: Using low friction, long-life compound material, to avoid the direct contact between metals, repair and replacement are easy and convenient.

 

 

Seal

Normal temperature using nitrile butadiene rubber. High or low temperatures using fluorine rubber or silicone rubber

 

Control

Double acting, single acting

 

Annex

Available accessories: Reversing solenoid valve, Limit switch/ position monitoring switch, positioner, hand wheel device.

 

Precautions

 

 When performing large-scale inspections of actuators, it is necessary to completely discharge the remaining pressure in the pipeline.
When the actuator is in operation, do not step into the transmission or place your hand in the transmission.
To prevent an electric shock, do not touch the wire connection (exposed live body) on the actuator with the solenoid valve or switch.
Be sure to test in the event of a power outage. Also, do not touch these charged bodies with wet hands.

 

Pneumatic valve accessories

 

Annex 1 Reversing solenoid valve
The electronic control operation for "turning on" or "off" the pneumatic valve acts as a switching air source. The solenoid valve complies with the NAMUR connection standard and can be divided into a mounted type and a separate type. The double-acting pneumatic actuator is equipped with a two-position five-way solenoid valve, and the single-acting two-position three-way solenoid valve can be manually operated. The structure is simple, compact and has a long life. The solenoid valve coil voltage has AC220V or DC24V low power consumption, and the explosion-proof encapsulation Ex m II BT4 and the explosion-proof Ex d II BT4 are optional. The company's solenoid valve is directly mounted on the actuator in a plate type.

Working principle Electromagnetic valve junction box wiring diagram

 

 

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 2Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 3

 

Annex 2 Limit switch (also known as echo)
The limit switch box feeds back the pneumatic valve position signal to the control room, directly mounted on the top of the pneumatic actuator, in accordance with VDI/VDE3845, built-in mechanical switch or magnetic induction proximity switch, and optional explosion-proof.
Built-in 2 mechanical switches 2-SPDT wiring diagram
Rating: 16A 1/2HP 125/250V AC 0.6A 125V DC 0.3A 250V DC

 

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 4

 

Annex 3 Air filter pressure reducing valve
Including air pressure reducing valve, filter, oil mister.

Function: gas source is stable, clean, and lubricates moving parts

 

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 5

 

Annex 4 Electrical Positioner
The electric positioner is one of the important accessories of the pneumatic regulating valve. It accepts 4-20mA control valve opening degree, and is divided into mechanical type and intelligent electronic type.

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 6

 

Mechanical positioner wiring diagram

 

Silicone Rubber Pneumatic Air Actuator , High Pressure Pneumatic Actuator 7

 

Common faults and handling

 

 

Stage Fault Description Fault Cause Remedy
I/P check I/P air pressure output does not change Gas source failure Check if the air supply valve is open
      Check if the pipeline is blocked
    Control signal failur Check if the signal line is disconnected
      Control signal line "+" "-" is reversed
    I/P damage replacement
Adjustment valve The regulating valve will not move or the action will not be in place No air source Check if the air supply valve is open
    Gas circuit connection is incorrect Check the correctness of the gas circuit connection
    Gas circuit blockage Check and ventilate the circuit
    Give way Check for leaks and fix
    Adjustment valve stuck Contact the aircraft to solve
    Regulating valve and accessory connection is not strong Check the connection of the regulating valve and accessories, it should be fixed firmly, no looseness
    I/P failure Check I/P
    Solenoid valve is not powered or de-energized Check solenoid valve power
    Valve not in automatic position Switch to automatic position
    DCS has a mandatory signal Contact run processing
    Some valves must be reset to the local after losing gas. Local reset
  Position transmitter current output is not allowed Not securely connected to the regulating valve Check the connection, it should be fixed firmly, no looseness
    Zero position, range has changed Re-zeroing, measuring the whole
    Position transmitter is damaged Potentiometer is bad
  Travel switch does not work Incorrect installation re-install
    Loose travel switch readjust
    Travel switch damage replace
  Regulating valve moves in the opposite direction Locator direction adjustment error readjust

Contact Details